Trip relay, monostables and latching
Trip relays, with reduced switching times (e.g. <10ms) compared to standard relays (e.g. < 20ms).
| Model | Contacts | Nominal current | Coil input | Heavy duty use | Rolling sock | Notes | |
|---|
| RGR | 2
| 5
| DC | | | Fast-acting < 2,5ms, reed tecnology | |
| RGMV16X | 4
| 10
| DC or AC | | | Fast-acting (trip relay) <8ms, monostable | |
| RGMV17X | 4
| 10
| DC | | | Fast-acting (trip relay) <8ms, monostable, High-Burden (HB) | |
| RMMV12X | 8
| 10
| DC or AC | | | Fast-acting (trip relay) <8ms, monostable | |
| RMMV16X | 8
| 10
| DC | | | Fast-acting (trip relay) <8ms, monostable, High-Burden (HB) | |
| RMMV11 | 12
| 10
| DC or AC | | | Fast-acting (trip relay) <10ms, monostable | |
| RMMV17 | 12
| 10
| DC | | | Fast-acting (trip relay) <10ms, monostable, High-Burden (HB) | |
| RGMV | 4
| 10
| DC | | | Fast-acting (trip relay) < 8ms, monostable | |
| RMMV | 8
| 10
| DC | | | Ultra Fast-acting (trip relay) < 6ms, monostable | |
| RMMZ11 | 8
| 10
| DC | | | Fast-acting (trip relay) < 8ms, monostable | |
| RGBV14x | 4
| 10
| DC or AC | | | Fast-acting (trip relay) <10ms, latching | |
| RGBV16X | 4
| 10
| DC | | | Fast-acting (trip relay) <10ms, latching, High-Burden (HB) | |
| RMBV12X | 8
| 10
| DC or AC | | | Fast-acting (trip relay) <10ms, latching | |
| RMBV14X | 8
| 10
| DC | | | Fast-acting (trip relay) <10ms, latching, High-Burden (HB) | |
| RMBV15 | 12
| 10
| DC or AC | | | Fast-acting (trip relay) <10ms, latching | |
| RMBV16 | 12
| 10
| DC | | | Fast-acting (trip relay) <10ms, latching, High-Burden (HB) | |
Forcibly guided contacts
The contacts are mechanically linked. These relays use special features to ensure the make contacts (normally open) cannot assume the same state as the break contacts (normally-closed).
| Model | Contacts | Nominal current | Coil input | Heavy duty use | Rolling sock | Notes | |
|---|
| RCG | 2
| 10
| DC or AC | | | Forcibly guided contacts, weld-no-transfer, EN61810-3 type A | |
| RDG | 4
| 10
| DC or AC | | | Forcibly guided contacts, weld-no-transfer, EN61810-3 type A | |
| RGG | 4
| 12
| DC or AC | | | Forcibly guided contacts, weld-no-transfer, EN61810-3 type A, high breaking capacity | |
| RGK | 4
| 12
| DC or AC | | | Timed with forcibly guided contacts, weld-no-transfer, EN61810-3 type A, high breaking capacity | |
| RMGX | 8
| 10
| DC or AC | | | Forcibly guided contacts, weld-no-transfer, EN61810-3, type A, high breaking capacity | |
Latching
Relay with 2 latched contact positions. The contacts change state with an electrical pulse supplied by one of the 2 power coils. To restore the starting position of the contacts, the other coil must be powered.
| Model | Contacts | Nominal current | Coil input | Heavy duty use | Rolling sock | Notes | |
|---|
| RGB | 4
| 12
| DC or AC | | | | |
| RMBX | 8
| 10
| DC or AC | | | Multi-contacts | |
| RMB | 8
12
20
| 10
| DC or AC | | | Multi-contacts | |
Instantaneous, monostable
The contacts change position instantaneously when the relay is powered and return instantaneously to their initial position when power is shut off.
| Model | Contacts | Nominal current | Coil input | Heavy duty use | Rolling sock | Notes | |
|---|
| RCM | 2
| 10
| DC or AC | | | Compact | |
| RDM | 4
| 10
| DC or AC | | | Compact | |
| RGM | 4
| 12
| DC or AC | | | Very high breaking cap. | |
| RMMX | 8
| 10
| DC or AC | | | Multi-contacts | |
| RMM | 8
12
20
| 10
| DC or AC | | | Multi-contacts | |
Time delayed, pick-up, drop-out, logic
The contacts change status with time delay T with respect to the energization or de-energization of the relay input circuit. Logical function relays can be used for various functions, including CYCLIC, ONE-SHOT, etc.
| Model | Contacts | Nominal current | Coil input | Heavy duty use | Rolling sock | Notes | |
|---|
| RGK | 4
| 12
| DC or AC | | | Timed with forcibly guided contacts, weld-no-transfer, EN61810-3 type A, high breaking capacity | |
| RDT | 4
| 10
| DC or AC | | | Delai ON or delai OFF | |
| RDL | 2
| 10
| DC or AC | | | Flashers | |
| RGL | 2
| 12
| DC or AC | | | Flashers | |
| RDTE15 | 4
| 10
| DC | | | Delai OFF, no power supply | |
| RDTE16 | 4
| 10
| DC or AC | | | Delai OFF, no power supply | |
| RGTO | 2
| 12
| DC or AC | | | Delai OFF, no power supply | |
| RMTZ04 | 4
| 10
| DC | | | RFI (Italian Railway) approved, T2 type relay | |
| RMTZ05 | 4
| 10
| DC | | | RFI (Italian Railway) approved, T1 type relay | |
| RMTZ07 | 4
| 10
| DC | | | RFI (Italian Railway) approved, T3 type relay | |
Measurement
The contacts change status for a defined input power value.
| Model | Contacts | Nominal current | Coil input | Heavy duty use | Rolling sock | Notes | |
|---|
| TD | 4
| 10
| DC or AC | | | Current monitoring | |
| MAMF12 | 2
| 10
| DC | | | Insulation between input and contact: 12kV | |
| MAVF1X | 2
| 10
| DC | | | Measuring relay, insulation 15kV | |
Coil continuity check
Monostable or bistable relays, coil continuity supervision and monitoring by means of a built-in auxiliary relay.
| Model | Contacts | Nominal current | Coil input | Heavy duty use | Rolling sock | Notes | |
|---|
| RMN | 4
8
16
| 10
| DC or AC | | | Monostable, coil continuity check | |
| RMD | 4
8
16
| 10
| DC or AC | | | Latching, coil continuity check | |