Railway, Rolling stock

Forcibly guided contacts

The contacts are mechanically linked. These relays use special features to ensure the make contacts (normally open) cannot assume the same state as the break contacts (normally-closed).

ModelContactsNominal currentCoil inputHeavy duty useRolling sockNotes
RCG

2

10

DC or ACForcibly guided contacts, weld-no-transfer, EN61810-3 type A
RDG

4

10

DC or ACForcibly guided contacts, weld-no-transfer, EN61810-3 type A
RGG

4

12

DC or ACForcibly guided contacts, weld-no-transfer, EN61810-3 type A, high breaking capacity
RGK

4

12

DC or ACTimed with forcibly guided contacts, weld-no-transfer, EN61810-3 type A, high breaking capacity
RMGX

8

10

DC or ACForcibly guided contacts, weld-no-transfer, EN61810-3, type A, high breaking capacity

Latching

Relay with 2 latched contact positions. The contacts change state with an electrical pulse supplied by one of the 2 power coils. To restore the starting position of the contacts, the other coil must be powered.

ModelContactsNominal currentCoil inputHeavy duty useRolling sockNotes
OKBA

4

10

DC or AC8 C/O as option
BAS8

8

10

DC or AC
RMBX

8

10

DC or ACMulti-contacts

Instantaneous, monostable

The contacts change position instantaneously when the relay is powered and return instantaneously to their initial position when power is shut off.

ModelContactsNominal currentCoil inputHeavy duty useRolling sockNotes
POK

2

5

DC or ACCompact, magnetic arc blow-out
POKS

2

10

DC or ACCompact, magnetic arc blow-out
BIPOK

4

5

DC or ACCompact, magnetic arc blow-out
BIPOKS

4

10

DC or ACCompact, magnetic arc blow-out
TRIPOK

6

5

DC or ACCompact, magnetic arc blow-out
TRIPOKS

6

10

DC or ACCompact, magnetic arc blow-out
QUADRIPOK

8

10

DC or ACCompact, magnetic arc blow-out
OKUIC

4

10

DC or ACTRENITALIA approved, 100.000.000 operations
OKSCD

4

10

DC or ACVery high breaking capacity, 100.000.000 operations
FOKB

4

13

DCDouble break, NF-F 62002 compliant

Time delayed, pick-up, drop-out, logic

The contacts change status with time delay T with respect to the energization or de-energization of the relay input circuit. Logical function relays can be used for various functions, including CYCLIC, ONE-SHOT, etc.

ModelContactsNominal currentCoil inputHeavy duty useRolling sockNotes
TMM2

4

10

DC or ACMultifunction relay, 10 functions, 2 timed + 2 inst. contacts
TMM4

4

10

DC or ACMultifunction relay, 10 functions, 4 timed contacts
TM2E TMS2E

4

5

10

DC or ACWide scale, Delay ON (2) + INST (2)
TM4E TMS4E

4

5

10

DC or ACWide scale, Delay ON
TM2R TMS2R

4

5

10

DC or ACWide scale, Delay OFF (2) + INST (2)
TM4R TMS4R

4

5

10

DC or ACWide scale, Delay OFF
TOKE

4

10

DC or ACDelay ON, 100.000.000 operations
TOKR

4

10

DC or ACDelay OFF, 100.000.000 operations
OKTF

4

10

DC or ACDelay OFF, no power supply
OKTA

4

5

DC or ACDelay ON
OKTR

4

5

DC or ACDelay OFF
OKRE

4

5

DC or ACDelay ON
OKRR

4

5

DC or ACDelay OFF
UTMEDCStatic time delay unit, delay ON
UTMRDCStatic time delay unit, delay OFF
TOK-L

4

5

DC or ACFlashers, 100.000.000 operations
OKRE-L

4

5

DC or ACFlashers
TOK-FP

4

5

DC or ACOne-shot, 100.000.000 operations
OKRE-FP

4

5

DC or ACOne-shot
CLE

4

5

DC or ACFlashers, fixed time
RGK

4

12

DC or ACTimed with forcibly guided contacts, weld-no-transfer, EN61810-3 type A, high breaking capacity

Measurement

The contacts change status for a defined input power value.

ModelContactsNominal currentCoil inputHeavy duty useRolling sockNotes
MOK-V2

2

5

DC or ACMeasuring relay, voltage threshold
OKPH

2

5

ACSequence & detection phase