Energy, Power generation and distribution
Instantaneous, monostable
The contacts change position instantaneously when the relay is powered and return instantaneously to their initial position when power is shut off.
POK|2 C/O - 5 A
- Compact instantaneous plug-in relays with 2 contacts, 5 A
- Magnetic arc blow-out as standard
- Excellent shock and vibration resistance, suitable for rolling stock
- Option available for use in geothermal sites

POKS|2 C/O - 10 A
- Compact instantaneous plug-in relays with 2 contacts, 10 A
- Magnetic arc blow-out as standard
- Excellent shock and vibration resistance, suitable for rolling stock
- Option available for use in geothermal sites

BIPOK|4 C/O - 5 A
- Compact instantaneous plug-in relays with 4 contacts, 5 A
- Magnetic arc blow-out as standard
- Excellent shock and vibration resistance, suitable for rolling stock
- Option available for use in geothermal sites

BIPOKS|4 C/O - 10 A
- Compact instantaneous plug-in relays with 4 contacts, 10 A
- Magnetic arc blow-out as standard
- Excellent shock and vibration resistance, suitable for rolling stock
- Option available for use in geothermal sites

TRIPOK|6 C/O - 5 A
- Compact instantaneous plug-in relays with 6 contacts, 10 A
- Magnetic arc blow-out as standard
- Excellent shock and vibration resistance, suitable for rolling stock
- Option available for use in geothermal sites

TRIPOKS|6 C/O - 10 A
- Compact instantaneous plug-in relays with 6 contacts, 10 A
- Magnetic arc blow-out as standard
- Excellent shock and vibration resistance, suitable for rolling stock
- Option available for use in geothermal sites

QUADRIPOK|8 C/O - 10 A
- Compact instantaneous plug-in relays with 8 contacts, 10 A
- Magnetic arc blow-out as standard
- Excellent shock and vibration resistance, suitable for rolling stock
- Option available for use in geothermal sites

ESAPOK|12 C/O - 10 A
- Compact instantaneous plug-in relays with 12 contacts, 10 A
- Magnetic arc blow-out as standard
- Excellent shock and vibration resistance, suitable for rolling stock
- Option available for use in geothermal sites

OK|4-8-12 C/O - 10 A
- Plug-in relays with 4 instantaneous contacts, 10 A
- Solid and rugged construction for intensive duty, 100,000,000 operations
- Excellent shock and vibration resistance
- Ample clearance between open contact elements, 5 kV insulation

OKS|4-8-12 C/O - 10 A
- Plug-in relay with 4 instantaneous contacts, 10 A, with magnetic arc blow-out
- Solid and rugged construction for intensive duty, 100,000,000 operations
- Excellent shock and vibration resistance
- Ample clearance between open contact elements, 5 kV insulation

OKFC|4-8-12 C/O - 10 A
- Plug-in relay with 4 instantaneous contacts, 10 A
- Operating range 80…120% Un
- Solid and rugged construction for intensive duty, 100,000,000 operations
- Excellent shock and vibration resistance
- Ample clearance between open contact elements, 5 kV insulation

OKSFC|4-8-12 C/O - 10 A
- Plug-in relay with 4 instantaneous contacts, 10 A, with magnetic arc blow-out
- Operating range 80…120% Un
- Solid and rugged construction for intensive duty, 100,000,000 operations
- Excellent shock and vibration resistance
- Ample clearance between open contact elements, 5 kV insulation
.jpg)
OKUIC|4 C/O - 10 A
- Plug-in relay with 4 instantaneous contacts, 10 A, with magnetic arc blow-out
- Suitable for rolling stock applications
- Solid and rugged construction for intensive duty, 100,000,000 operations
- Excellent shock and vibration resistance, suitable for rolling stock
- Ample clearance between open contact elements, 5 kV insulation
.jpg)
OKSCD|4 C/O - 10 A
- Plug-in relays with 4 instantaneous contacts, 10 A
- Magnetic arc blow-out and silver cadmium oxide contacts
- Solid and rugged construction for intensive duty, 100,000,000 operations
- Excellent shock and vibration resistance
- Ample clearance between open contact elements, 5 kV insulation

OKSGcCd|4 C/O - 10 A
- Plug-in relay with 4 instantaneous contacts, 10 A
- Magnetic arc blow-out and silver cadmium oxide contacts
- Ample clearance between open contact elements (> 4mm), 5 kV insulation
- Solid and rugged construction for intensive duty, 100,000,000 operations
- Excellent shock and vibration resistance

OKB184|4 C/O - 10 A
- Plug-in relay with 4 instantaneous contacts, 10 A, with magnetic arc blow-out
- K3 EDF approved, compliant with HM 63/95/125/C specifications
- Solid and rugged construction for intensive duty
- Excellent shock and vibration resistance
- Ample clearance between open contact elements, 5 kV insulation

RCM|2 C/O - 10 A
PRODUCT NOTICE
Relay cover change
For more information click here
- Compact instantaneous plug-in relays with 2 contacts, 10 A
- Self-cleaning knurled contacts
- Optional magnetic arc blow-out
- Fitted with mechanical optical contact status indicator as standard
.jpg)
RDM|4 C/O - 10 A
PRODUCT NOTICE
Relay cover change
For more information click here
- Compact instantaneous plug-in relays with 4 contacts, 10 A
- Self-cleaning knurled contacts
- Optional magnetic arc blow-out
- Fitted with mechanical optical contact status indicator as standard
.jpg)
RGM|4 C/O - 12 A
PRODUCT NOTICE
Relay cover change
For more information click here
- Instantaneous plug-in relays with 4 contacts, 12 A
- Solid and rugged construction for intensive duty
- Very high electrical life expectancy and exceptional endurance
- Self-cleaning knurled contacts
- Optional magnetic arc blow-out
.jpg)
RMMX|8 C/O - 10 A
- Instantaneous plug-in relays with 8 contacts, 10 A
- More compact dimensions
- Solid and rugged construction for intensive duty
- Very high electrical life expectancy and exceptional endurance
- Self-cleaning knurled contacts

RMM|8-12-20 C/O - 10 A
- Instantaneous plug-in relays with 8-12-20 contacts, 10 A
- Solid and rugged construction for intensive duty
- Very high electrical life expectancy and exceptional endurance
- Self-cleaning knurled contacts