Trip relay, monostables and latching
Trip relays, with reduced switching times (e.g. <10ms) compared to standard relays (e.g. < 20ms).
| Model | Contacts | Nominal current | Coil input | Heavy duty use | Rolling sock | Notes | |
|---|
| RGR | 2
| 5
| DC | | | Fast-acting < 2,5ms, reed tecnology | |
| RV LV16 | 6
| 5
| DC | | | Ultra Fast-acting (trip relay) < 6ms, monostable | |
| RGMV | 4
| 10
| DC | | | Fast-acting (trip relay) < 8ms, monostable | |
| RMMV | 8
| 10
| DC | | | Ultra Fast-acting (trip relay) < 6ms, monostable | |
| RMMZ11 | 8
| 10
| DC | | | Fast-acting (trip relay) < 8ms, monostable | |
Forcibly guided contacts
The contacts are mechanically linked. These relays use special features to ensure the make contacts (normally open) cannot assume the same state as the break contacts (normally-closed).
| Modello | Contatti | In | Alimentazione | Utilizzo intensivo | Materiale rotabile | Note | |
|---|
| RCG | 2
| 10
| DC or AC | | | Contatti a guida forzata, weld-no-transfer, EN61810-3 tipo A | |
| RDG | 4
| 10
| DC or AC | | | Contatti a guida forzata, weld-no-transfer, EN61810-3 tipo A | |
| RGG | 4
| 12
| DC or AC | | | Contatti a guida forzata, weld-no-transfer, EN61810-3 tipo A, elevato potere di interruzione | |
| RGK | 4
| 12
| DC or AC | | | Temporizzato con contatti a guida forzata, weld-no-transfer, EN61810-3 tipo A, elevato potere di interruzione | |
| RMGX | 8
| 10
| DC or AC | | | Contatti a guida forzata, weld-no-transfer, EN61810-3 tipo A, elevato potere di interruzione | |
Latching
Relay with 2 latched contact positions. The contacts change state with an electrical pulse supplied by one of the 2 power coils. To restore the starting position of the contacts, the other coil must be powered.
| Modello | Contatti | In | Alimentazione | Utilizzo intensivo | Materiale rotabile | Note | |
|---|
| OKBA | 4
| 10
| DC or AC | | | 8 C/O in opzione | |
| BAS8 | 8
| 10
| DC or AC | | | | |
| RGB | 4
| 12
| DC or AC | | | | |
| RMBX | 8
| 10
| DC or AC | | | Multicontatto, elevato potere di interruzione, dimensione ridotta | |
| RMB | 8
12
20
| 10
| DC or AC | | | Multicontatto, elevato potere di interruzione | |
Instantaneous, monostable
The contacts change position instantaneously when the relay is powered and return instantaneously to their initial position when power is shut off.
| Modello | Contatti | In | Alimentazione | Utilizzo intensivo | Materiale rotabile | Note | |
|---|
| POK | 2
| 5
| DC or AC | | | Compatto, soffiatore magnetico | |
| POKS | 2
| 10
| DC or AC | | | Compatto, soffiatore magnetico | |
| BIPOK | 4
| 5
| DC or AC | | | Compatto, soffiatore magnetico | |
| BIPOKS | 4
| 10
| DC or AC | | | Compatto, soffiatore magnetico | |
| TRIPOK | 6
| 5
| DC or AC | | | Compatto, soffiatore magnetico | |
| TRIPOKS | 6
| 10
| DC or AC | | | Compatto, soffiatore magnetico | |
| QUADRIPOK | 8
| 10
| DC or AC | | | Compatto, soffiatore magnetico | |
| ESAPOK | 12
| 10
| DC or AC | | | Compatto, soffiatore magnetico | |
| OK | 4
8
12
| 10
| DC or AC | | | 8 e 12 C/O in opzione, disponibile in versione per Marina Militare, 100.000.000 manovre | |
| OKS | 4
8
12
| 10
| DC or AC | | | 8 e 12 C/O in opzione, 100.000.000 manovre, soffiatore magnetico | |
| OKFC | 4
8
12
| 10
| DC or AC | | | 8 e 12 C/O in opzione, 100.000.000 manovre, basso consumo | |
| OKSFC | 4
8
12
| 10
| DC or AC | | | 8 e 12 C/O in opzione, 100.000.000 manovre, soffiatore magnetico e basso consumo | |
| OKUIC | 4
| 10
| DC or AC | | | Approvato TRENITALIA, 100.000.000 manovre | |
| OKSCD | 4
| 10
| DC or AC | | | Elevatissimo potere di interruzione, 100.000.000 manovre | |
| OKSGcCd | 4
| 10
| DC or AC | | | Elevatissimo potere di interruzione, distanza tra contatti 4mm, 100.000.000 manovre | |
| OKB184 | 4
| 10
| DC | | | Conforme K3 | |
| RCM | 2
| 10
| DC or AC | | | Compatto, soffiatore magnetico in opzione | |
| RDM | 4
| 10
| DC or AC | | | Compatto, soffiatore magnetico in opzione | |
| RGM | 4
| 12
| DC or AC | | | Elevatissimo potere di interruzione | |
| RMMX | 8
| 10
| DC or AC | | | Multicontatto, elevato potere di interruzione, dimensione ridotta | |
| RMM | 8
12
20
| 10
| DC or AC | | | Multicontatto, elevato potere di interruzione | |
Time delayed, pick-up, drop-out, logic
The contacts change status with time delay T with respect to the energization or de-energization of the relay input circuit. Logical function relays can be used for various functions, including CYCLIC, ONE-SHOT, etc.
| Modello | Contatti | In | Alimentazione | Utilizzo intensivo | Materiale rotabile | Note | |
|---|
| TMM2 | 4
| 10
| DC or AC | | | Relè multifunzione, 10 funzioni, 2 contatti temporizzati + 2 istantanei | |
| TMM4 | 4
| 10
| DC or AC | | | Relè multifunzione, 10 funzioni, 4 contatti temporizzati | |
| TM2E TMS2E | 4
| 5
10
| DC or AC | | | Ampia scala di regolazione, temporizzato all'eccitazione (2) + INST (2) | |
| TM4E TMS4E | 4
| 5
10
| DC or AC | | | Ampia scala di regolazione, temporizzato all'eccitazione | |
| TM2R TMS2R | 4
| 5
10
| DC or AC | | | Ampia scala di regolazione, temporizzato al rilascio (2) + INST (2) | |
| TM4R TMS4R | 4
| 5
10
| DC or AC | | | Ampia scala di regolazione, temporizzato al rilascio | |
| TOKE | 4
| 10
| DC or AC | | | Temporizzato all'eccitazione, 100.000.000 manovre | |
| TOKR | 4
| 10
| DC or AC | | | Temporizzato al rilascio, 100.000.000 manovre | |
| OKTF | 4
| 10
| DC or AC | | | Temporizzato al rilascio, nessuna alimentazione ausiliaria | |
| OKTA | 4
| 5
| DC or AC | | | Temporizzato all'eccitazione | |
| OKTR | 4
| 5
| DC or AC | | | Temporizzato al rilascio | |
| OKRE | 4
| 5
| DC or AC | | | Temporizzato all'eccitazione | |
| OKRR | 4
| 5
| DC or AC | | | Temporizzato al rilascio | |
| UTME | | | DC | | | Unità temporizzatrice statica, temporizzazione all'eccitazione | |
| UTMR | | | DC | | | Unità temporizzatrice statica, temporizzazione al rilascio | |
| TOK-L | 4
| 5
| DC or AC | | | Lampeggiante (ciclico), 100.000.000 manovre | |
| OKRE-L | 4
| 5
| DC or AC | | | Lampeggiante (ciclico) | |
| TOK-FP | 4
| 5
| DC or AC | | | Funzione di passaggio, 100.000.000 manovre | |
| OKRE-FP | 4
| 5
| DC or AC | | | Funzione di passaggio | |
| CLE | 4
| 5
| DC or AC | | | Lampeggiante (ciclico) a tempo fisso | |
| RGK | 4
| 12
| DC or AC | | | Temporizzato con contatti a guida forzata, weld-no-transfer, EN61810-3 tipo A, elevato potere di interruzione | |
| RDT | 4
| 10
| DC or AC | | | Temporizzato all'eccitazione o al rilascio | |
| RDL | 2
| 10
| DC or AC | | | Lampeggiante (ciclico) | |
| RGL | 2
| 12
| DC or AC | | | Lampeggiante (ciclico), elevato potere di interruzione | |
| RDTE15 | 4
| 10
| DC | | | Temporizzato al rilascio, nessuna alimentazione ausiliaria | |
| RDTE16 | 4
| 10
| DC or AC | | | Temporizzato al rilascio, nessuna alimentazione ausiliaria | |
| RGTO | 2
| 12
| DC or AC | | | Temporizzato al rilascio, nessuna alimentazione ausiliaria | |
| RMTZ04 | 4
| 10
| DC | | | Approvato RFI, relè tipo T2 | |
| RMTZ05 | 4
| 10
| DC | | | Approvato RFI, relè tipo T1 | |
| RMTZ07 | 4
| 10
| DC | | | Approvato RFI, relè tipo T3 | |
Measurement
The contacts change status for a defined input power value.
| Modello | Contatti | In | Alimentazione | Utilizzo intensivo | Materiale rotabile | Note | |
|---|
| MOK-V2 | 2
| 5
| DC or AC | | | Relè di misura a soglia di tensione | |
| OKPH | 2
| 5
| AC | | | Supervisione del senso ciclico delle fasi | |
| MOK-PH2 | 2
| 5
| AC | | | Supervisione del senso ciclico delle fasi | |
| TD | 4
| 10
| DC or AC | | | Monitoraggio della corrente | |
| MAMF12 | 2
| 10
| DC | | | Isolamento tra ingresso e contatti: 12kV | |
| MAVF1X | 2
| 10
| DC | | | Relè di misura, isolamento 15kV | |
Coil continuity check
Monostable or bistable relays, coil continuity supervision and monitoring by means of a built-in auxiliary relay.
| Modello | Contatti | In | Alimentazione | Utilizzo intensivo | Materiale rotabile | Note | |
|---|
| RMN | 4
8
16
| 10
| DC or AC | | | Monostabile con controllo continuità bobina | |
| RMD | 4
8
16
| 10
| DC or AC | | | Bistabile con controllo continuità bobina | |